Skip to content

machin0r/CIMSII-Midas_Ink_Control

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

12 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

CIMSII-Midas_Ink_Control

Python library for communicating with a Megnajet/Xaar CIMS II/HV/Midas ink system.

This library uses RS422 communication with the CIMS II/Midas ink system.

Dependencies

This program requires the use of pySerial

Usage

  1. Create a Midas object
import midas_comms

Midas = midas_comms.Midas()
  1. The Midas object opens communications by calling the create_serial_connection(port) function with the port name as an argument. Baud rate, etc. can also be passed as arguments, but are set at a default. This function creates a Midas_Serial object tied to the Midas object.
Midas.create_serial_connection('/dev/ttyUSB0')

# The default settings are used as arguments below
Midas.create_serial_connection('/dev/ttyUSB0', baudrate=115200,
                                 stopbits=serial.STOPBITS_ONE,
                                 parity=serial.PARITY_NONE,
                                 databits=serial.EIGHTBITS, timeout=2):
  1. The different parameters of the Midas can be accessed through different sub-classes, as well as some through the main Midas class:
Midas() - general control and information
Midas.Status() - alarms and status bits
Midas.Pressures() - infeed, meniscus  parameters
Midas.Temperatures() - heater parameters
Midas.Pumps() - recirc and meiscus pumps
Midas.Purge() - purge pressures and control

Common Enable Bits Combinations

There are a few common enable bits that will most likely be used in all programs:

Value Ink Enable Command Recirc. Command Fill Pump Command Description
36922 0 0 0 Off
32896 0 0 1 Off
36933 1 0 0 Off
37001 1 1 0 Turns on the recirculation and enables printing
32897 1 0 1 Fills reservoir - needs 32905 sending first
32905 1 1 1 Fills reservoir when needed, prints

NOTE: There is a quirk with having just the fill pump on, the system must be fully enabled, and then the recirculation and enable printing disabled.

They can be set using:

Midas.set_enable_bits("32905")  # Fully enable the Midas system

This is equivilent to sending SEB,32905\r through the serial port.